From: The flat-plate plant-microbial fuel cell: the effect of a new design on internal resistances
Ri(Ωm2) | i (A/m2) | Expected P (W/m2) | Measured P (W/m2) | Δ P (W/m2) |
---|---|---|---|---|
1.283 | 0.295 | 0.213 | 0.244 | 0.032 |
1.380 | 0.069 | 0.069 | 0.013 | −0.056 |
1.444 | 0.058 | 0.059 | 0.010 | −0.050 |
2.302 | 0.054 | 0.053 | 0.008 | −0.045 |
2.354 | 0.054 | 0.053 | 0.008 | −0.044 |
2.396 | 0.169 | 0.118 | 0.081 | −0.037 |
2.404 | 0.044 | 0.043 | 0.005 | −0.038 |
2.982 | 0.145 | 0.097 | 0.059 | −0.038 |
3.060 | 0.142 | 0.095 | 0.057 | −0.038 |
3.542 | 0.029 | 0.029 | 0.002 | −0.027 |
4.169 | 0.091 | 0.066 | 0.023 | −0.042 |
9.668 | 0.033 | 0.026 | 0.003 | −0.023 |