Skip to main content

Table 2 Flow rates and stream composition at the extractor

From: Energy-efficient recovery of fermented butyric acid using octyl acetate extraction

Stream Feed Solvent Extract Wastewater
Composition
 Water 0.9929 0 0.0616 0.9986
 Acetic acid 0.0014 0 0.0019 0.0012
 Butyric acid 0.0058 0.0001 0.0558 0
 Octyl acetate 0 0.9999 0.8807 0.0001
Flow rates (kmol/h) 545.3 49.3 55.9 538.7