Skip to main content

Table 4 Evaporator design parameters obtained from a WinGEMS simulation of a seven-effect evaporator using initial conditions of measured wastewater parameters

From: Integration of wastewater treatment into process design of lignocellulosic biorefineries for improved economic viability

Parameter

Unit

Value

Input

Influent flow rate, Q

L/h

340,000

Influent temperature, Qtemp

°C

80

Influent fraction solids, Xin

–

0.085

Steam pressure, Spress

bar

4.4

Steam temperature, Stemp

°C

115

Output

Steam demand, Sin

kg/h

55,200

Evaporator area, SA

m2

2500

Effluent fraction solids, Xout

–

0.61

Effluent pressure, Pout

bar

0.28

Capacity, C

kg/h

295,000

Economy, E

kg/kg

5.34

Syrup flow rate, Qsyrup

L/h

47,700

Condensate flow rate, Qout

L/h

292,000